Suitable fire extinguishing equipment shall be immediately available in the work area and shall be maintained in a state of readiness for instant use. 350 - 354) Welding, Cutting and Soldering Safety (Hot Work) (Standard Operating Procedure) Purpose . C [^. 1926.913 - Blasting in excavation work under compressed air. When arc welding is performed in wet or high-humidity conditions, employees shall use additional protection, such as rubber pads or boots, against electric shock. 1926.858 - Removal of steel construction. Means of detecting an increase in atmospheric hazard levels in the event the ventilation system stops working; Each person, by name, currently serving as an attendant; The individual, by name, currently serving as entry supervisor, and the signature or initials of each entry supervisor who authorizes entry; The hazards of the permit space to be entered; The measures used to isolate the permit space and to eliminate or control permit space hazards before entry;
An employer may use the alternate procedures specified in paragraph (e)(2) of this section for entering a permit space only under the conditions set forth in paragraph (e)(1) of this section. Shall not have objects that might either damage the safety device or obstruct the valve placed on top of the cylinder when in use. Nothing shall be placed on top of a cylinder or associated parts when the cylinder is in use. Input power terminals, top change devices and live metal parts connected to imput circuits shall be enclosed and accessible only by means of insulated tools. 1926.251 - Rigging equipment for material handling. OSHA Laws & Regulations 1926 Regulations (Standards - 29 CFR) By Standard Number Standard Number > 1926 1926 - Table of Contents 1926 Subpart A - General 1926.1 - Purpose and scope. Hot work. If a plug or safety device leaks, the cylinder shall be tagged, removed from service, and moved to a location where the leak will not be hazardous. Such personnel shall be instructed as to the specific anticipated fire hazards and how the firefighting equipment provided is to be used. Hot electrode holders shall not be dipped in water. The valve of a fuel gas cylinder shall not be cracked where the gas would reach welding work, sparks, flame, or other possible sources of ignition. 0000054473 00000 n
Drums, containers or hollow structures that have contained flammable or combustible substances shall either be filled with water or cleaned, and shall then be ventilated. 1926 Subpart R App H - Double Connections: Illustration of a Clipped End Connection and a Staggered Connection: Non-Mandatory Guidelines for Complying with 1926.756(c)(1). Welding & cutting operations, conducted outside authorized hot work areas, includes extensive procedures for fire prevention. 1926.1002 - Protective frames (roll-over protective structures, known as ROPS) for wheel-type agricultural and industrial tractors used in construction. Any employee who enters the space, or that employee's authorized representative, must be provided with an opportunity to observe the testing required by this paragraph (e)(2)(vi). Overnight and at the change of shifts, the torch and hose shall be removed from the confined space. The employer shall instruct all employees involved in hot work operations as to potential fire hazards and the use of firefighting equipment. Inside of buildings, cylinders shall be stored in a well-protected, well-ventilated, dry location, at least 20 feet (6.1 m) from highly combustible materials such as oil or excelsior. 1926.854 - Removal of walls, masonry sections, and chimneys. Hose couplings shall not unlock or disconnect without rotary motion. 1926.1204 - Permit-required confined space program. If continuous monitoring is not used, periodic monitoring is required. Standard for Fire Prevention During Welding, Cutting, and Other Hot Work This standard presents provisions to prevent injury, loss of life, and loss of property from fire or explosion as a result of hot work projects such as welding, heat treating, grinding, and similar applications producing or using sparks, flames, or heat. Shall have valve protection caps in place except when in use, hooked up or secured for movement. Ground return cables shall have current-carrying capacity equal to or exceeding the total maximum output capacities of the welding or cutting units served. 67 66
1926 Subpart F - Fire Protection and Prevention. They shall not be hoisted or transported by means of magnets or choker slings. Ask how long hot work permits are valid. Ventilation and employee protection in welding, cutting and heating -. The employer must implement measures to protect employees from the hazard before any subsequent entry takes place. Assuming a hot work permit is required, it must be issued by a "Permit Authorizing Individual (PAI)." It is the responsibility of the department employing and supervising Hose shall be inspected before use. 1926.3 - Inspections - right of entry. Use professional pre-built templates to fill in and sign documents online faster. In accordance with OSHA standards, contractors are required to apply for these permits through the company's permit-authorizing individual (PAI). Oil shall not be used to lubricate caps; Shall be hoisted only while secured, as on a cradle or pallet, and shall not be hoisted by magnet, choker sling or cylinder caps; Shall be moved only by tilting or rolling on their bottom edges; Shall have valves closed when cylinders are empty, being moved or stored; Shall be secured upright except when hoisted or carried; Shall not be freed when frozen by prying the valves or caps with bars or by hitting the valve with a tool; Shall not be exposed to sparks, hot slag, or flame; Shall not be permitted to become part of electrical circuits or have electrodes struck against them to strike arcs; Shall not be used as rollers or supports; Shall not have contents used for purposes not authorized by the supplier; Shall not be used if damaged or defective; Shall not have gases mixed within, except by gas suppliers; Shall be stored so that oxygen cylinders are separated from fuel gas cylinders and combustible materials by either a minimum distance of 20 feet (6.1 m) or a barrier having a fire-resistance rating of 30 minutes; and. 0000013465 00000 n
1926.350 (a) (3) Cylinders shall be moved by tilting and rolling them on their bottom edges. Welding, cutting and heating on preservative coatings. Valve protection caps shall be in place and secured. ___ Smoke detectors in the area of hot work have been covered to prevent false alarms. Unless cylinders are firmly secured on a special carrier intended for this purpose, regulators shall be removed and valve protection caps put in place before cylinders are moved. 1926.1404 - Assembly/Disassemblygeneral requirements (applies to all assembly and disassembly operations). Yann Wehrling, vice-prsident de la rgion le-de-France, charg de la Transition cologique, et Patrice Leclerc, maire de Gennevilliers et Prsident du groupe Front De Gauche la . 1926.14 - Federal contract for "mixed" types of performance.
0000003987 00000 n
When parallel sections of oxygen and fuel gas hose are taped together, not more than 4 inches out of 12 inches shall be covered by tape. Hot Work Permit . 1926.1103 - 13 Carcinogens (4-Nitrobiphenyl, etc.). "Hot work" means riveting, welding, flame cutting or other fire or spark-producing operation. Occupational Safety and Health Administration, Outreach Training Program (10- and 30-hour Cards), OSHA Training Institute Education Centers, Severe Storm and Flood Recovery Assistance, Inert-gas Metal-Arc Welding (Non-ferrous) 1/16- to 5/32-inch electrodes. Only cable free from repair or splice for 10 feet (3 m) from the electrode holder shall be used unless insulated connectors or splices with insulating quality equal to that of the cable are provided. Unless a host employer or controlling contractor has or will have employees in a confined space, it is not required to enter any confined space to collect the information specified in this paragraph (h). 1926.1419 - Signalsgeneral requirements. Those measures can include, but are not limited to, the lockout or tagging of equipment and procedures for purging, inerting, ventilating, and flushing permit spaces. Oxygen shall not be directed at oily surfaces, greasy clothes, or within a fuel oil or other storage tank or vessel. 0000075649 00000 n
When oxygen and fuel gas hoses are taped together, not more than four (4) of each 12 inches (10.16 cm of each 30.48 cm) shall be taped. The controlling contractor and entry employer(s) must coordinate entry operations when: More than one entity performs permit space entry at the same time; or. Employees in areas not protected from the arc by screening shall be protected by appropriate filter lenses in accordance with paragraph (h) of this section. 1926.1414 - Wire ropeselection and installation criteria. Sharing procedures. The hot work permit helps the permit authorizing individual, hot work operator, and fire watch recognize potential hazards. Each employee must leave the space immediately; The space must be evaluated to determine how the hazard developed; and. 1929 wheat penny. 1926.1411 - Power line safetywhile traveling. Defective hose, or hose in doubtful condition, shall not be used. Inform exposed employees by posting danger signs or by any other equally effective means, of the existence and location of, and the danger posed by, each permit space; and
1926.1429 - Qualifications of maintenance & repair employees. 1926.30 - Shipbuilding and ship repairing. When there are changes in the use or configuration of a non-permit confined space that might increase the hazards to entrants, or some indication that the initial evaluation of the space may not have been adequate, each entry employer must have a competent person reevaluate that space and, if necessary, reclassify it as a permit-required confined space. hot work have been covered with a wet rag. 1926.804 - Definitions applicable to this subpart. sb`aY No damaged or defective cylinder shall be used. 1926.305 - Jacks-lever and ratchet, screw, and hydraulic. Except as specified in paragraphs (f)(3)(ii) and (f)(3)(iii) of this section, when hot work is performed in a confined space the employer shall ensure that: General mechanical or local exhaust ventilations shall be provided; or. 1926.24 - Fire protection and prevention. osha hot work permit requirements 1926; hot work permit checklist; hot work hazards and control measures pdf; sample hot work permit for cutting or welding; How to Edit Your Hot Work Permit Osha Standard Online. Occupational Safety and Health Administration, Outreach Training Program (10- and 30-hour Cards), OSHA Training Institute Education Centers, Severe Storm and Flood Recovery Assistance. Fuel gas hose and oxygen hose shall be easily distinguishable from each other. 0000009657 00000 n
0000000016 00000 n
A designated person shall test the atmosphere and determine that it is not hazardous before hot work is performed on or in such structures. 1910.252 (a) (1) (ii) Guards. The permit acts as a checklist to ensure precautions are taken to prevent the ignition of inflammable or combustible materials in a 35-foot area surrounding the work. Oxygen and fuel hoses shall not be interchangeable. 1926.64 - Process safety management of highly hazardous chemicals. The cylinder valve shall always be opened slowly to prevent damage to the regulator. 0000028894 00000 n
0000009131 00000 n
1926 Subpart H - Materials Handling, Storage, Use, and Disposal. Any special wrench required for emergency closing shall be positioned on the valve stem during cylinder use. Hot Work permit Every job site involving Hot Work requires a permit to document the hazards and the safeguards in place to ensure the planned hot work does not cause a fire. 0000065789 00000 n
Working with ignition sources near flammable materials is referred to as "hot work." Welding, soldering and cutting are examples of hot work. 1926.703 App - General Requirements for Formwork. 0000014279 00000 n
When a cable other than the lead mentioned in paragraph (e)(2)(ii) of this section wears and exposes bare conductors, the portion exposed shall not be used until it is protected by insulation equivalent in performance capacity to the original. 1926.1208 - Duties of authorized entrants. The control apparatus of arc welding machines shall be enclosed, except for operating wheels, levers, and handles. Lou, Paris 11eme, recherche des personnes motives et comptentes qui partagent notre enthousiasme pour la gastronomie, le vin et l'hospitalit pour devenir Chef de Parties dans notre quipe . Hose subjected to flashback or showing evidence of severe wear or damage shall be tested to twice the normal working pressure but not less than 200 p.s.i. The tips below can help you fill out Osha Hot Work Permit Form Pdf easily and quickly: Open the template in the full-fledged online editor by hitting Get form. The employer shall ensure that employees performing hot work in the open air that involves any of the metals listed in paragraphs (f)(3)(i) and (f)(3)(ii) of this section shall be protected by respirators in accordance with the requirements of 1910.134, and those working on beryllium-containing base or filler metals shall be protected by supplied air respirators, in accordance with the requirements of 1910.134. 1926.97 - Electrical protective equipment. 1926.1406 - Assembly/Disassemblyemployer procedures--general requirements. Gas hose storage boxes shall be ventilated. 1926.450 - Scope, application and definitions applicable to this subpart. Gas welding equipment shall be maintained free of oil and grease. Fire extinguishing equipment suitable for the location shall be immediately available and shall be maintained in readiness for use at all times. The area supervisor is responsible. When welders are exposed to their own arc or to each other's arc, they shall wear filter lenses complying with the requirements of paragraph (h) of this section. For manifolded or coupled cylinders, at least one wrench shall be immediately available. 1926 Subpart L App E - Drawings and Illustrations. If testing and inspection during that entry demonstrate that the hazards within the permit space have been eliminated or isolated, the permit space may be reclassified as a non-permit confined space for as long as the hazards remain eliminated or isolated; The entry employer must document the basis for determining that all hazards in a permit space have been eliminated or isolated, through a certification that contains the date, the location of the space, and the signature of the person making the determination. Before hot work is commenced on surfaces covered by a preservative coating of unknown flammability, a test shall be made by a designated person to determine the coating's flammability. Any employee who enters the space, or that employee's authorized representative, must be provided an opportunity to observe the pre-entry testing required by this paragraph. Includes how employers must control respiratory hazards in the space; testing the internal atmosphere; and what to document for each entry. 1926.1428 - Signal person qualifications. 0000006244 00000 n
1926.95 - Criteria for personal protective equipment. When the hot work operation is such that normal fire prevention precautions are not sufficient, additional personnel shall be assigned to guard against fire during hot work and for a sufficient time after completion of the work to ensure that no fire hazard remains. Boxes used for the storage of gas hose shall be ventilated. The entry permit that documents compliance with this section and authorizes entry to a permit space must identify: The date and the authorized duration of the entry permit; The authorized entrants within the permit space, by name or by such other means (for example, through the use of rosters or tracking systems) as will enable the attendant to determine quickly and accurately, for the duration of the permit, which authorized entrants are inside the permit space;
Empty containers shall be removed to a safe area apart from hot work operations or open flames. For Compliance With . A space classified by an employer as a permit-required confined space may only be reclassified as a non-permit confined space when a competent person determines that all of the applicable requirements in paragraphs (g)(1) through (4) of this section have been met: If the permit space poses no actual or potential atmospheric hazards and if all hazards within the space are eliminated or isolated without entry into the space (unless the employer can demonstrate that doing so without entry is infeasible), the permit space may be reclassified as a non-permit confined space for as long as the non-atmospheric hazards remain eliminated or isolated; The entry employer must eliminate or isolate the hazards without entering the space, unless it can demonstrate that this is infeasible. Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour. When entrance covers are removed, the opening must be immediately guarded by a railing, temporary cover, or other temporary barrier that will prevent an accidental fall through the opening and that will protect each employee working in the space from foreign objects entering the space. %\9
Training. 1926 Subpart S App A - Decompression Tables. Other OSHA regulations, however, do not (although it is often advisable to retain certain documents even if retention is. 3. Defective hose shall not be used. The written program must be made available prior to and during entry operations for inspection by employees and their authorized representatives. Drums and containers which contain or have contained flammable or combustible liquids shall be kept closed. 1926 Subpart R App A - Guidelines for establishing the components of a site-specific erection plan: Non-Mandatory Guidelines for Complying with 1926.752(e). 1926 Subpart R App E - Training: Non-mandatory Guidelines for Complying with 1926.761. Oregon OSHA provides a variety of publications, including; guide books, brochures, forms, hazard alerts, fact sheets, posters, cards, stickers, reports, and checklists on a variety of workplace health and safety topics. Arc welding or cutting equipment having a functional defect shall not be used. When hot work must be performed in a location that is not free of fire hazards, all necessary precautions shall be taken to confine heat, sparks, and slag so that they cannot contact flammable or combustible material. Sharing policies. 0000036037 00000 n
Surfaces prepared with chlorinated solvents shall be thoroughly dry before welding is performed on them. Hot work in confined spaces. Displaying signs in areas where performing hot work is prohibited. 0000038376 00000 n
Once again, thoroughly examine all OSHA codes for details. Occupational Safety & Health Administration. 1926.500 - Scope, application, and definitions applicable to this subpart. INTRODUCTION . This section contains the required practices and procedures necessary to protect employees from fire and explosion hazards associated with hot work. Get Form. Entry into the permit space under the terms of paragraph (e)(1) of this section is performed in accordance with the requirements of paragraph (e)(2) of this section. 1926.407 - Hazardous (classified) locations. Before heat is applied to a drum, container, or hollow structure, a vent or opening shall be provided for the release of any built-up pressure during the application of heat. No person other than the gas supplier shall attempt to mix gases in a cylinder. Permit space entry is performed at the same time that any activities that could foreseeably result in a hazard in the permit space are performed. Welding, Cutting, and Other Hot Work. 1926.153 - Liquefied petroleum gas (LP-Gas). Before a regulator is removed from a cylinder valve, the cylinder valve shall always be closed and the gas released from the regulator. 0000010051 00000 n
1926.22 - Recording and reporting of injuries. Grounding circuits shall have resistance low enough to permit sufficient current to flow to cause the fuse or circuit breaker to interrupt the current. 0000033273 00000 n
Attendant means an individual stationed outside one or more permit spaces who assesses the status of authorized . This requirement may be met by inserting a reference on the entry permit as to the means used, such as a roster or tracking system, to keep track of the authorized entrants within the permit space. 1926.35 - Employee emergency action plans. Yes, permits for performing hot work are required by both OSHA and the National Fire Protection Association (NFPA), in addition to the local fire code. 1926.914 - Definitions applicable to this subpart. Employees in areas not protected from the arc by screening shall be protected by appropriate filter lenses in accordance with the requirements of paragraph (h) of this section. 1926.702 - Requirements for equipment and tools. H\n0z Regulators and gauges. 1926.417 - Lockout and tagging of circuits. A single hose having more than one gas passage shall not be used. Variations of one or two shade numbers are permissible to suit individual preferences. For additional details not covered in this subpart, applicable technical portions of American National Standards Institute, Z49.1-1967, Safety in Welding and Cutting, shall apply. Compressed gas cylinders shall be secured in an upright position at all times except, if necessary, for short periods of time while cylinders are actually being hoisted or carried. When welders are exposed to their own arc or to each other's arc, filter lenses complying with the requirements of paragraph (h) of this section shall be worn to protect against flashes and radiant energy. If hazards arise within a permit space that has been reclassified as a non-permit space under paragraph (g) of this section, each employee in the space must exit the space.